MANUFACTURER · EST. 2010 · JIANGSU CCCF 3C · ISO 9001 · GB 14561 GLOBAL EXPORT-READY
Home › Fire Extinguisher Cabinet
Global Product Line · Factory-Direct OEM

Fire Extinguisher Cabinets, Built to Your Spec

Factory-direct fire extinguisher cabinets in the three mountings buyers specify — surface mounted, semi-recessed and fully recessed — for 5, 10 and 20 lb portable extinguishers. Cold-rolled steel in white or red, SUS 304 brushed stainless, or anodised aluminium; full-glass, duo-panel, bubble or solid doors; cam lock or break-glass. Also sold as a fire extinguisher box; specified in North America under CSI section 10 44 13. We supply importers and distributors directly from our own factories — your brand, your drawing, from a trial order to full containers.

16+
Years
3
Production Bases
7d
Sample Lead Time
24h
Quote Reply
Fire extinguisher cabinet — wall mounted single door cabinet with glass panel for a portable extinguisher
Recessed · semi-recessed · surface
ISO 9001 · 14001 · 45001Certified management systems
CCCFChina compulsory fire-product certification
EN 60529Third-party enclosure ingress-protection test
15,000 / monthCabinets across our three factories
Sample firstBuild one to your drawing, approve it, then order

What a Good Extinguisher Cabinet Has to Do

An extinguisher cabinet has three jobs: hold the extinguisher at the height the code requires, let anyone open it in seconds, and not stick out into the corridor far enough to be a hazard. Everything else — door style, finish, trim — follows from the building.

NFPA 10

Height and access

For extinguishers up to 40 lb the top of the unit sits no more than 5 ft above the floor; over 40 lb, no more than 3.5 ft; and the bottom stays at least 4 in clear. The cabinet is sized and mounted so the extinguisher lands in that band.

ADA

Projection into the corridor

Where the leading edge is between 27 and 80 in above the floor, a cabinet should project no more than 4 in into a circulation path. That is why semi-recessed and fully recessed cabinets exist — and why the trim return you choose matters.

SAY

Fire-rated cabinets

A cabinet installed in a fire-rated wall has to be a listed fire-rated assembly. We do not make listed fire-rated cabinets and will tell you so rather than quote one. For non-rated walls — the majority of installations — no listing applies to the cabinet.

Fire Extinguisher Cabinet Sizes & Configurations

Sizes follow the extinguisher, then the mounting. All are made to order in inches or millimetres; a non-standard size costs no more in tooling.

By extinguisher size and mounting

ModelSuitsTub inside (in, W×H×D)Tub inside (mm)Wall rough opening (in)MountingDoor
EC-55 lb / 2.3 kg portable9.5 × 24 × 5241 × 610 × 12710.5 × 25 × 5.25Recessed, semi-recessed, surfaceFull view, duo panel or solid
EC-1010 lb / 4.5 kg portable9.5 × 24 × 6241 × 610 × 15210.5 × 25 × 6.25Recessed or semi-recessed (1.5 in or 2.5 in trim)Full view, break-glass or solid
EC-2020 lb / 9 kg portable12 × 27 × 8305 × 686 × 20313 × 28 × 8.25Recessed, semi-recessed or surfaceFull view, duo panel or solid
EC-2x20Two 20 lb units side by side20 × 27 × 8508 × 686 × 20321 × 28 × 8.25Fully recessed, semi-recessed or surfaceTwo doors or one wide door
EC-SURSurface, 5–10 lb13 × 27.5 × 6 (overall)330 × 699 × 152none — no opening cutSurface onlyFlush solid, break-glass or acrylic
EC-CUSAny extinguisher or combinationTo your drawingUp to 3,000 mmTo your drawingAnyTo your specification

Rough openings for recessed and semi-recessed cabinets run about 1 in larger than the tub in height and width, and the trim sets how deep the opening must be: a 10 lb cabinet needs 6.25 in fully recessed, 5 in with 1.5 in trim and 2.5 in with the 4 in ADA trim. Send the extinguisher model and the wall build-up and we return the exact opening with the quotation.

Mounting, trim, doors and materials

ChoiceWhat we makeWhen it is used
Surface mountedFull body on the wall face, no openingRetrofit, masonry and industrial walls; simplest to install
Semi-recessedBody partly in the wall with a rolled or flat trim returning 1.5, 2.5, 3 or 4 inCorridors where projection must stay within about 4 in
Fully recessedBody inside the wall, flat trim or trimless faceLobbies and finished spaces where a flush face is wanted
Door stylesFull glass, vertical or horizontal duo panel, solid steel, bubble, frameless acrylicGlass and duo panels show the extinguisher; solid doors suit dusty or public areas
Glazing and locksClear acrylic, tempered glass or break-glass, with a cam lock, flush pull or break-glass handleBreak-glass where tampering is a risk; cam lock where the cabinet must stay shut
MaterialsCold-rolled steel powder-coated white or red; SUS 304 no. 4 brushed; anodised aluminium; brass-look PVDSteel for general work, stainless for coastal, food and prestige interiors

Sheet thickness 0.8–2.0 mm. Trimless faces and concealed hinges are available where the architect wants no visible frame.

Options buyers ask for

  • Door lettering — FIRE EXTINGUISHER, or bilingual wording for the market
  • Instruction decal, inspection tag holder and a break-glass hammer with chain
  • Cam lock, cylinder lock, flush pull, or a break-glass panel
  • Weather-sealed outdoor version with a gasketed door and drip lip
  • Combination cabinet: extinguisher beside a hose reel, hydrant valve or first-aid kit
  • Free OEM — your brand, colour, lettering and packaging

Parts of a fire extinguisher cabinet: body, door and frame, glass or acrylic panel, lock or latch, hinges, extinguisher bracket, trim or architrave, lettering. Replacement glass, keys, locks and brackets are supplied for our cabinets.

Choosing the mounting

Fully recessedFlush with the wall face. Needs a wall cavity deeper than the box — check the stud depth before specifying.
Semi-recessedPart in the wall, trim returning 1.5–4 in. The usual answer in corridors, and the one that keeps projection within the ADA limit.
Surface mountedNo opening needed. Projects the full depth, so keep it outside circulation paths or below 27 in leading edge.
Mounting heightSet so the extinguisher, not the box, meets NFPA 10: top of the unit within 5 ft of the floor for units up to 40 lb, bottom at least 4 in clear.

Tell us the wall type, the finish thickness and the extinguisher model, and we return the rough opening and trim size with the quotation.

What the Factory Can Build

Straight from the workshop capability sheet. Building fire cabinets in Jiangsu, China since 2010, for importers, distributors and own-brand sellers.

Sheet thickness
0.8 – 2.0 mm to your specification
Materials
Cold-rolled steel · SUS 201 / 304 / 316 · aluminium · galvanised steel
Finish
Powder coating; white and RAL 3000 red in stock — any RAL from 300 pcs; brushed, hairline and mirror stainless
Maximum single piece
Up to 3,000 mm cabinet length for powder-coated units
Door types
Single, double, triple, sliding, up-swing, glass, acrylic, frangible; cam locks and break-glass
Made to drawing
Any size, trim return, cut-out or lettering — we build to your DWG or spec section

Fire Extinguisher Cabinet Price — How FOB Quoting Works

We are the factory. Prices are FOB and quoted per model and quantity; there is no retail list because the specification moves the number so much.

What moves the price

Size, sheet thickness, steel versus stainless, door style and glazing, trim type, lock, and lettering.

Quotation

FOB pricing within 24 hours from your spec, schedule or drawing. Wholesale tiers for distributors.

Sampling

One cabinet built to your drawing in about 7 working days. Sample cost is borne by the buyer and credited against the first order on request.

OEM & branding

Free OEM: your brand, colour, lettering and packaging with no tooling fee. We already build under distributors’ own brands.

Packing

Knocked-down or assembled, in export cartons with corner and glass protection; container mix across models is fine.

Shipping

Sea freight to your named port, FOB Xiamen. Lead time confirmed on the quotation.

What we don’t make: GRP, plastic or timber enclosures · heated cabinets · sheet thinner than 0.8 mm. The cabinet shell carries no UL, FM, LPCB or Kitemark approval. Certificate requirements for your market? Tell us before you order — we will say plainly whether we can meet them.

Fire Extinguisher Cabinets in Real Projects

Our cabinets on site — offices, hospitals, schools, chemical plants, petrol stations and container terminals. Real installations, not renderings.

Downloads & Drawings

Datasheet with cabinet sizes by extinguisher, rough openings and trim returns, plus the US-size drawing pack as PDF and AutoCAD DXF — free, with no sign-up. The DXF opens in AutoCAD (save it as a DWG if you need one) and imports into Revit; other sizes are drawn on request.

Fire Extinguisher Cabinet — Buyer FAQ

What size fire extinguisher cabinet do I need?

Size follows the extinguisher, and US practice quotes the tub width first. A 5 lb unit fits a 9.5 × 24 × 5 in tub, a 10 lb unit the same face at 6 in deep, a 20 lb unit a 12 × 27 × 8 in tub, and two 20 lb units side by side a 20 × 27 × 8 in tub. In millimetres those are 241 × 610 × 127, 241 × 610 × 152, 305 × 686 × 203 and 508 × 686 × 203. Cut the wall opening 10.5 × 25 in for the small tubs, 13 × 28 in for a 20 lb unit and 21 × 28 in for the twin. The 30 in figure sometimes quoted for a 20 lb cabinet is the trim outside dimension, not the tub.

What is the difference between recessed, semi-recessed and surface mounted?

A fully recessed cabinet sits inside the wall and finishes flush. A semi-recessed cabinet sits partly in the wall with a trim that returns 1.5 to 4 in, which keeps the projection inside the usual 4 in limit for corridors. A surface mounted cabinet fixes to the wall face and needs no opening, projecting the full depth.

How much does a fire extinguisher cabinet cost from your factory?

There is no single price. Cost follows size, sheet thickness, steel versus stainless, door style and glazing, trim type and quantity. A plain powder-coated steel cabinet is a fraction of a brushed stainless one with a rolled trim. Send your spec or schedule and we return an FOB quotation within 24 hours with wholesale tiers.

Do you make fire-rated extinguisher cabinets?

No. A cabinet in a fire-rated wall has to be a listed fire-rated assembly, and we do not hold that listing — we will say so rather than quote one. For non-rated walls, which is most installations, no listing applies to the cabinet and we build to your specification.

What is the difference between a fire extinguisher cabinet and a fire extinguisher box?

Nothing consistent — they are the same product under two names. Buyers in North America and Europe usually say cabinet; buyers in the Middle East, Africa and South Asia often say box. Outdoor units with a solid weather-sealed door are also called extinguisher boxes.

Can you OEM fire extinguisher cabinets for distributors?

Yes — free OEM: your brand, colour, lettering, instruction decal and packaging with no tooling fee. We already produce extinguisher cabinets, hose cabinets and hydrant boxes under distributors’ own brands in several markets.

Do you supply stainless steel and outdoor versions?

Yes. SUS 304 brushed for interiors and coastal work, SUS 316 for beachfront and chemical plant — see our stainless steel extinguisher cabinet page. Outdoor cabinets get a gasketed door and drip lip in steel or stainless.

What is the minimum order for a trial, and how do we move to full containers?

Carbon steel cabinets 50 units, stainless steel 30 units — a first order can be smaller. We build one sample cabinet to your drawing, you approve it, then the batch runs; several models can share one container. Every approved model keeps its drawing number, so a repeat order goes by number with no new sample. See our importer & distributor program.

What is your lead time, and can you keep up with repeat orders?

About 7 working days for a sample once the drawing is approved, then 25–40 days for mass production depending on quantity and finish. Our three factories make 15,000 cabinets a month between them, scheduled by order, so a large or repeat order can run across more than one factory.

Our market requires a certificate for the cabinet — can you supply it?

What we hold: CCCF 3C, ISO 9001 / 14001 / 45001 and third-party EN 60529 test reports for the enclosure. The cabinet shell carries no UL, FM, LPCB or Kitemark approval, and we do not apply for a country’s certificate on our own. If your tender asks for a certificate on the cabinet itself, tell us before you order — we will say plainly whether we can meet it.

Also searched as: fire extinguisher box · recessed fire extinguisher cabinet · semi recessed fire extinguisher cabinet · surface mounted fire extinguisher cabinet · wall mounted fire extinguisher cabinet · outdoor fire extinguisher cabinet · stainless steel fire extinguisher cabinet · fire extinguisher cabinet size · fire extinguisher cabinet dimensions · fire extinguisher cabinet mounting height · extinguisher cabinet · fire extinguisher housing

Related Guides

Factory Pricing — From a Trial Order to Full Containers

Send your spec, a schedule or just quantities and extinguisher sizes — our export team replies with a factory-direct FOB quotation within 24 hours.

Request a Quotation→

Get a Factory
Quote Today.

Whether you import under your own brand, distribute in your market or source for a project — send your drawing or BOQ and our export team responds within 24 hours.

W
WhatsApp / WeChat +86 139-1237-6837
@
Export Inquiries [email protected]
⌖
Headquarters No. 33 Xingang Ave, Jingjiang EDZ, Jiangsu, China
⏱
Response Time Within 24 Hours · GMT+8

Request a Quote

Most orders are OEM-customized. Send drawings, specs or photos — we respond within 24 hours.
📋 Used for label customization & local standards
💬 Backup contact in case your email bounces
📧 Your quotation will be sent here — please double-check the spelling
💡 Most orders are OEM-customized — dimensions, labels in your market's language, logo, color, door style all configurable. Free.
📎 Drawings or a BOQ? Reply to our confirmation email with the file, or send it on WhatsApp.
Chat with us · WhatsApp